loading

NDS

The MicroTesla NDS, New Digitized Sensor, is a completely new “drop-in” replacement sensor for QDT products.

It has a one-piece chassis made from a solid billet of 6061-T6 aluminum and it uses NO end adapters. The ends are machined to fit the Customers snubber (shock isolator) and MWD controller chassis ends. No end adapters mean no “loose” end adapters and no end adapter misalignment.

The NDS has (1) electronic board for all functions including core drive, mag sense, analog to digital conversion and power control.

The NDS uses (3) Q-flex accelerometers and (2) two-axis MicroTesla magnetometers. The ultra-strong, stiffchassis means that the accelerometer and magnetometer misalignments are eliminated.

The NDS is a 175 deg C instrument which uses the many new high temperatures (210 deg C +) electronic components.

Physical

Electrical

Enviornmental

Mechanical and Environmental Specifications

ParameterMinimumMaximumUnits
Outside Diameter*1.37
3.5
inches
cm
Length*29.3
74.4
inches
cm
Operating Temperature0
+ 32
175
347
°C
°F
Survival Temperature– 40
– 40
190
374
°C
°F
Vibration, Random25g RMS, 25-500 Hz
Shock1000½ msec and ½ sine

Instrument Accuracy Specifications

ParameterMinimumUnits
Inclination accuracy, absolute*± 0.08degrees
Inclination spread on axial rotation at 90° Inc< 0.08degrees
Azimuth accuracy, absolute, 90° Inc± 0.4degrees
Azimuth spread axial rotation, 45° through 90°< 0.35degrees
Total face accuracy, axial rotation at 90° Inc± 0.7degrees
Total g field accuracy± 2.5mG
Total H field accuracy, absolute± 180nT
Total H field spread< 150nT
Magnetic dip accuracy± 0.2degrees
Dip angle spread< .25degrees

* Absolute accuracy is achieved when the instrument is tested in a controlled environment using a calibrated and certified reference position